Heat Pump Blowing Cold Air: Defrost, AUX and EM Heat, and What to Fix
As an Amazon Associate we earn from qualifying purchases. Links marked “(paid link)” are affiliate links. Full disclosure.
On this page
Cool air from the registers with the heat on can be alarming in your first winter with a heat pump, and often nothing is wrong. A heat pump moves heat in from outdoors, so its air runs cooler than a furnace's, and in cold, damp weather it pauses to defrost its outdoor coil. When something is wrong, it is usually a thermostat setting, a dirty filter, an outdoor unit that is blocked or iced over, or backup heat that isn't coming on.
This page covers what is normal, including AUX and EM heat, then the causes from the easiest to check, what you can safely fix, and where the technician takes over. If your heat comes from a gas furnace instead, see furnace blowing cold air.
If you smell gas, stop here. Leave the house, do not switch lights, appliances, or phones on or off on the way out, and call the gas utility or 911 from outside, whether or not your backup heat is a gas furnace. If you smell burning plastic or hot wiring, turn the system off at the thermostat and at the air handler's power switch, and don't run it again until a technician has checked it. If there is smoke or fire, get everyone out and call 911 from outside. The outdoor unit usually runs on a 220- or 240-volt circuit: switch the system off at the thermostat and at the disconnect box beside the unit before you clear it, and never open its panels or touch refrigerant lines or wiring. And keep a CO alarm on every level and outside sleeping areas.
First, Check What Is Normal
Heat pump air is cooler than furnace air. Carrier puts heat pump supply air at roughly 85 to 100°F while heating, against roughly 120 to 140°F from a gas furnace, so air that is heating the house well can feel cool on your hand. The test is whether the house reaches the setting; long run times in the cold are normal if it keeps up, Bryant says.
Defrost comes with steam and noise. The outdoor coil runs 10 to 20°F colder than the outdoor air, Trane says, so frost can form even in the low 40s. To clear it, the heat pump reverses into cooling mode for a few minutes to warm the outdoor coil. The outdoor fan may stop, you may hear a whoosh or running water, and steam can rise from the unit, all normal per Trane, Bryant, and Daikin. A cycle typically lasts about 5 to 15 minutes (Lennox, Bryant) or 5 to 10 (Carrier), and Trane says its demand-defrost systems usually finish in 3 to 5.
AUX on the thermostat is usually normal. Most heat pumps have backup heat: electric heat strips in the indoor air handler or, in a dual-fuel system, a gas furnace. The thermostat runs it automatically, and shows AUX, during defrost, when it is too cold for the heat pump alone, and after you raise the setting several degrees at once. Trane notes that some systems, including dual-fuel systems that don't run the furnace and heat pump together, blow cool air during defrost, which is also normal.
EM heat is a manual switch for a breakdown. EM (emergency) heat shuts the heat pump off and runs the backup alone. Carrier and Trane say to use it only when the heat pump has failed, and to call for service when you do. On electric strips it uses more energy: Carrier calls strip heat 100 percent efficient against as much as 300 percent for a heat pump, and ENERGY STAR says a heat pump can deliver up to three times more heat energy than the electricity it uses.
Most Likely Causes
- The thermostat is on COOL, AUTO, EM heat, or fan ON. COOL blows cold air, and a fan set to ON runs unheated air between heating cycles (Carrier, Lennox, Bryant); Bryant also warns that EM heat left on by mistake won't heat efficiently. Set HEAT, which ENERGY STAR prefers to AUTO so the system doesn't switch modes on an unusually warm day, and fan AUTO. If it started right after a new thermostat went in, a wrong O/B setting can swap heating and cooling; Google's fix is to switch O to B, or B to O, and retest (see thermostat not working).
- A dirty filter. A clogged filter chokes airflow, so the heat pump can blow lukewarm air or shut down (Carrier, Bryant), and Carrier says it can push the system onto backup heat even in mild weather. Hold the filter to the light, open registers, and clear returns of furniture and rugs. Replace it, arrow toward the air handler, per our filter guide; ENERGY STAR says check it monthly and change it at least every three months.
- The outdoor unit is blocked by snow, ice, leaves, or a cover. Snow, ice, leaves, or debris around the unit block the airflow it draws heat from (Lennox, DOE). Don't wrap it for winter: Lennox says heat pumps that run year-round should never be covered, Trane rules out solid covers, and Goodman warns that running an outdoor unit with a cover on can damage it. The most they allow is a top-only snow guard (Lennox) or a breathable cover made for the unit (Trane). A gutter dripping onto it adds ice (Lennox).
- Ice that doesn't clear. Carrier calls frost under about 1/4 inch normal; thicker ice, or ice that stays after defrost, is not. Lennox lists the causes: a failed defrost control board, timer, or sensor; low refrigerant from a leak; restricted airflow; a clogged drain pan; and freezing rain that overwhelms the defrost. Trane says defrosts that come constantly, or run longer while ice builds, need a dealer. These are a technician's job, as is a stuck reversing valve, which Carrier says shows up as a heat pump that cools but won't heat.
- The backup heat isn't coming on. If the air turns cold every defrost on a system with heat strips, or the house falls behind in deep cold, AUX may not be working. Carrier says the air handler, where the strips sit, has its own breaker, separate from the outdoor unit's, plus a power switch that looks like a light switch; check both. Switch a tripped breaker fully off, then on, once; if it trips again, leave it off and call (Bryant, Lennox). Our breaker page explains why. A dual-fuel backup is a furnace; see furnace blowing cold air.
- Deep cold below the balance point, or an undersized system. The balance point is the outdoor temperature at which the heat pump's capacity equals the home's heating demand; below it, supplemental heat is needed, and Carrier says it varies by heat pump, home, and system design. ENERGY STAR certification tests cold-climate heat pumps down to 5°F; ENERGY STAR says they keep working below that but heat most efficiently with backup heat. An undersized system struggles; ENERGY STAR and the DOE say contractors should size it with a Manual J load calculation. If the house has fallen behind in every cold snap since installation, have the backup heat and sizing checked.
What You Can Fix Yourself
- Set HEAT, not AUTO, COOL, or EM heat, with the fan on AUTO, and raise the setting a degree or two at a time, as Trane suggests.
- Replace the filter and open every register and return.
- With the power off, gently sweep snow off the top with a broom and clear snow and leaves from the sides (Lennox, Bryant, Trane). Don't pile shoveled snow against it.
- Keep about two feet clear around it, the general guide from Carrier, Lennox, and Bryant; your model's manual sets the actual clearances.
- Never chip or pry ice with a shovel, an ice pick, or any hard or sharp tool, which can puncture the coil (Bryant) and damage fins and fan blades (Lennox). Never pour hot water on it; Lennox says the sudden temperature change can crack parts.
- Take off any wrap or tarp, redirect a gutter that drains onto the unit, and reset a tripped breaker once.
When to Call a Pro
Refrigerant, the reversing valve, the defrost board and sensors, and electrical parts belong to a licensed HVAC technician; EPA rules under Section 608 of the Clean Air Act require certified technicians for refrigerant work and prohibit venting it. Call when ice won't clear or returns quickly, ice coats the refrigerant lines, or the outdoor fan won't spin after the ice melts (Lennox); when a breaker trips again; when AUX runs for more than an hour or two above 40°F (Trane); or when EM heat is your only heat. If you'll be away while you wait, keep the heat no lower than 55°F, the Red Cross minimum for protecting pipes.
Prevent It
ENERGY STAR recommends an annual pre-season check-up, heating in the fall; Lennox and Bryant suggest twice a year for a heat pump. Bryant's list includes the refrigerant charge in both modes and the capacitors and contactors; Lennox's adds the defrost controls. Check the filter monthly, clear the outdoor unit after every snowfall, and keep plants trimmed back. If snow buries the unit, ask about raising it: Mitsubishi Electric says contractors should mount it above the snow line. And pick a temperature and leave it: ENERGY STAR says heat pumps don't save energy from being turned down, and Carrier notes deep setbacks bring on AUX during recovery. The winter guide schedules it all.
Frequently Asked Questions
Why is my heat pump blowing cold air in heat mode?
Check for HEAT with the fan on AUTO. A few minutes of cooler air with steam outside is defrost. If it stays cold, replace the filter, clear the outdoor unit, and check the air handler breaker.
Why is my heat pump steaming outside?
It is defrosting: frost is melting off the outdoor coil, often with the fan stopped and a whooshing sound, and it stops within minutes. Smoke is different. If you smell burning, turn the system off and call; if there is smoke or fire, get out and call 911.
What is the difference between AUX and EM heat?
AUX is automatic backup heat for defrost, deep cold, or a big setpoint jump. EM heat is a manual setting that turns the heat pump off and runs the backup alone, only for a failed heat pump, per Carrier and Trane.
How do I unfreeze my heat pump?
Lennox's steps: turn the heat pump off at the thermostat, clear around it (power off at the disconnect first, as above), check the filter, and let it thaw, about two to four hours above freezing, with EM heat keeping the house warm. Never chip it or pour hot water on it. If it hasn't thawed in six to eight hours or refreezes, call.
The Bottom Line
Lukewarm air, steam outside, a few minutes of cooler air during defrost, and AUX in the cold are normal. Set HEAT with the fan on AUTO, change the filter, keep the outdoor unit clear and unwrapped, reset a tripped breaker once, and never chip ice. Ice that won't clear, AUX running for hours in mild weather, or cold air that doesn't stop is a technician's call; if the heat pump has failed, EM heat can carry the house until they arrive.
Sources
- Carrier — heat pump not heating (supply air about 85–100°F versus 120–140°F from a gas furnace; COOL or constant fan; outdoor unit usually on a 220- or 240-volt breaker; separate indoor and outdoor breakers; air handler power switch; filter restricts airflow; frost under 1/4 inch normal, thicker or lasting ice not; about 24 inches of clearance as a general guide, following model requirements; stuck reversing valve; typical defrost 5–10 minutes; refrigerant and electrical work for a professional) and what is auxiliary heat? (heat strips in the air handler; balance point definition, varying by system; AUX in defrost, deep cold, and after a large setpoint increase; EM heat shuts off the heat pump and is only for a breakdown; strips 100 percent efficient versus as much as 300 percent; dirty filters and setbacks bring on AUX).
- Trane — what is the heat pump defrost cycle? (coil 10–20°F below outdoor air; defrost in the 20s to low 40s; reversing to cooling; steam, swooshing sound, outdoor fan stopping; AUX during defrost; dual-fuel systems may blow cool air in defrost; demand defrost usually 3–5 minutes; call if defrost becomes constant or ice builds), auxiliary heat in a heat pump system (heat strips or dual-fuel furnace; AUX triggers; EM heat only for a failed heat pump, then call for service; AUX over an hour or two above 40°F; raise the setting a degree or two at a time), extreme winter weather preparation (no solid cover on a heat pump; breathable top cover; clear snow from the top and sides), and furnace smells like burning (what to do if you smell gas; burning plastic smell means turn it off and call for repair).
- Lennox — heat pump blowing cold air (thermostat on Cool or fan On; defrost 5–15 minutes; blocked outdoor unit; power off at the disconnect before clearing; reset a breaker once; no opening panels or touching refrigerant lines; two feet of clearance; twice-yearly tune-ups), what to do if your heat pump is frozen (causes of ice that won't clear; no chipping or hot water; broom, not sharp tools; don't pile snow against it; gutters; top-only snow guard; defrost controls checked at maintenance; thaw steps, timing, and EM heat; when to call, including iced refrigerant lines and a fan that won't spin), and should I cover my AC unit in the winter? (heat pumps that run year-round should never be covered).
- Bryant — heat pump not heating (EM heat left on by mistake; fan on ON; filter; sweep gently, two-foot perimeter, never chip with a hard tool; heat pump and air handler breakers, leave off if it trips again; defrost signs and 5–15 minutes; long run times in cold weather) and heat pump maintenance (refrigerant charge in both modes; capacitors, contactors, and wiring; twice-yearly service).
- Daikin — troubleshooting (heating pauses during defrost with a sound of flowing water; outdoor unit gives off water or steam).
- Goodman (Daikin Comfort Technologies) — should I cover my outdoor unit? (running the unit with a cover on can damage the system).
- Mitsubishi Electric — staying winter-weather ready (keep the outdoor unit clear of snow and ice; mount it above the snow line).
- Google Nest Help — heating and cooling reversed (cool air in heat mode; switch the O/B setting and retest).
- ENERGY STAR — air-source heat pumps (up to three times more heat energy than electricity used; too large or too small a system struggles; Manual J sizing; cold-climate testing down to 5°F, still working below it, most efficient with backup heat; steady temperature, no setbacks; HEAT rather than Auto mode), heat and cool efficiently (check the filter monthly; change it at least every three months), and maintenance checklist (annual pre-season check-up, heating in the fall).
- U.S. Department of Energy — Consumer Guide to Home Heating and Cooling (PDF) (Manual J sizing; keep weeds and debris away from outdoor heat pumps so air circulates).
- U.S. Environmental Protection Agency — Section 608 technician certification and stationary refrigeration and air conditioning (certified technicians; no venting of refrigerants during service).
- U.S. Consumer Product Safety Commission — Carbon Monoxide Information Center (CO alarms on every level and outside sleeping areas).
- U.S. Fire Administration — home fire escape plans (leave immediately in a fire; call the fire department from outside).
- American Red Cross — frozen pipes (heat no lower than 55°F when away).
Last reviewed September 28, 2026. General information, not professional advice — refrigerant, the reversing valve, defrost controls, heat strips, and electrical repairs belong to a licensed HVAC technician.