A GFCI outlet, the kind with TEST and RESET buttons, cuts the power when current leaks through a path it shouldn't take, such as water or a person. When one trips, it can take other outlets with it, sometimes in another room, so a bathroom, garage, or porch can go dead with no breaker tripped. Usually RESET brings everything back. When RESET won't stay in, or the GFCI trips again right away, it is telling you something: no power is reaching it, a fault is still on the circuit, it was wired backward, or it has worn out.

Below: the causes in the order to check them, and where the electrician takes over. You press buttons, unplug things, and reset breakers; opening an outlet box is electrical work (see our DIY vs. hire-a-pro guide). If a regular breaker keeps tripping instead, see breaker keeps tripping.

Water and electricity come first. If the outlet, the floor, or anything plugged in is wet, don't touch it; if water has reached any outlet or the panel, stay out and call your electric utility to cut the power from outside. Press RESET only with dry hands, on a dry floor. If you smell burning, see sparks, or an outlet is warm or discolored, leave it off and call an electrician; if there is smoke or fire, get everyone out and call 911 from outside. A GFCI that won't reset may be protecting you from a real ground fault, so never bypass it or swap it for an ordinary outlet. And before anyone removes a cover plate, the breaker goes off and a tester confirms the power is off.

First, Check What Is Normal

A trip is the GFCI doing its job. It compares the current going out with the current coming back; if they differ, some is leaking through another path, and it cuts the power. Leviton's specifications for a UL 943 Class A GFCI list a trip level of 5 milliamps, plus or minus 1 (4 to 6 mA), and Pass & Seymour gives the same figure; OSHA says a GFCI shuts off within as little as 1/40 of a second. Overloads and short circuits are the breaker's job; Leviton notes a GFCI outlet doesn't protect against them.

One GFCI can protect a string of outlets. Power from the panel arrives at the GFCI's LINE terminals; its LOAD terminals can feed ordinary outlets farther along the circuit, which it also protects, and when it trips, they all go dead. Leviton notes those outlets can be in different rooms and tells installers to mark each with a "GFCI Protected Outlet" sticker. A GFCI breaker in the panel protects the whole circuit.

Newer GFCIs have a status light. On Leviton's self-test models, green means working, solid or blinking red means a problem, and no light means tripped or no power. Pass & Seymour's radiant self-test GFCIs flash their light when the device fails.

Most Likely Causes

  1. A different GFCI tripped. If the dead outlet has no buttons, or its RESET does nothing, press RESET on every GFCI you can find: other bathrooms, the kitchen, garage, basement, laundry area, and outdoors. Check the panel for a breaker with a TEST button, too. A GFCI fed from another GFCI that tripped has no power until the first one is reset.
  2. No power is reaching it. A tripped breaker or a loose connection upstream leaves the GFCI without power, per Leviton, and GFCIs with a reset lockout, like its SmartlockPro line, won't reset without it. On Leviton's lighted models, no light and a RESET that won't hold can mean there is no power on the circuit. Reset a tripped breaker once, the safe way. If the breaker is on and the GFCI still won't reset, a loose connection is an electrician's job.
  3. The fault is still there. If something is still leaking current, the GFCI stays locked out or trips again. Leviton says to unplug everything from the GFCI and its downstream outlets, then press RESET. If it resets, plug things back in one at a time and leave the one that trips it unplugged; Leviton says it may be faulty. Legrand also names water as a cause, as in a wet outdoor or bathroom outlet, and says to press RESET only after the problem is fixed, such as once moisture has dried. But if water got into the outlet itself, Leviton says the GFCI needs replacing.
  4. It was wired backward. If a just-installed GFCI has never reset, suspect a line/load reversal: the wires from the panel went on the LOAD terminals. UL 943 requires GFCI outlets made since July 28, 2006, to cut power to their own face as well as the outlets downstream when wired this way. A new Leviton GFCI ships tripped and can't be reset until it is wired correctly and has power. Leviton's fix is to turn the power off and swap the LINE and LOAD wires, a job for a licensed electrician unless you are experienced and comfortable with electrical work. Leviton warns that an older GFCI wired backward can look fine yet won't trip on a ground fault.
  5. The GFCI has worn out. Leviton says moisture, surges, and wear can make a GFCI fail; the CPSC adds blackouts and other power disturbances. Under the same 2006 UL revision, a GFCI outlet that fails its internal test must signal that it needs replacing or stop delivering power. On Leviton's self-test models, a red light that doesn't clear after TEST and RESET, or a GFCI that won't reset, means replace it; so does one that is discolored, warm, or cracked, or holds plugs loosely. Older GFCIs may reset even after they stop protecting, Leviton says, which is why the monthly test matters.
  6. An appliance trips it with no obvious fault. Leviton says variable-speed motors and switching power supplies in modern appliances can put electrical noise on a circuit, and it redesigned its GFCIs to ignore it. Don't assume a nuisance trip, though: a GFCI that trips whenever one appliance runs may be catching a fault in it. Unplug it, and if the trips continue or the cause isn't obvious, Leviton's advice is to call an electrician.

What You Can Fix Yourself

For finding dead outlets and checking GFCIsKlein Tools RT250 GFCI Outlet Tester with LCD Displayplugs into a standard 3-slot, 120-volt outlet to show the voltage, common wiring faults, and how long a GFCI takes to trip.check price on Amazon

A plug-in tester shows which outlets are dead and when power is back; its button creates a 6 to 9 mA fault that should trip the GFCI protecting that outlet, per Klein. It doesn't replace the GFCI's TEST button, though. Klein limits it to 3-wire outlets and indoor use, says it detects only common wiring problems, says to check the GFCI's manual first, and says not to run its GFCI test on an outlet it shows as miswired, open ground included. Outdoors, use the GFCI's own TEST button. That rules out a GFCI that replaced an old two-slot outlet with no ground wire, labeled "No equipment ground" per the CPSC; there, the TEST button is the test. If the tester shows a fault, Klein says to call a qualified electrician.

When to Call a Pro

Call a licensed electrician, and leave the outlet off, when it won't reset with the breaker on and nothing plugged in; it keeps tripping and the cause isn't obvious; it fails the monthly test; it is warm, discolored, or cracked, holds plugs loosely, or has been wet; a new install won't reset and you aren't experienced with wiring; or the plug-in tester shows a fault. If an appliance gave you a tingle or shock, don't touch it again: the CPSC says to turn it off at the breaker and have an electrician check it.

Replacing a GFCI is a job for a licensed electrician. Leviton says a GFCI that fails its test should be replaced immediately by a licensed electrician, and the NFPA says GFCIs should be installed by a qualified electrician. The CPSC allows a homeowner with adequate wiring knowledge and skills to install one by its instructions, but says that when in doubt, contact a qualified electrician and do not attempt it yourself. The code is adopted and enforced locally, the CPSC notes, so ask your building department about permits and who may do the work. Leviton's instructions call for an electrician if the box holds more than four wires or a cable with more than two, not counting grounds, and ask that installers understand basic wiring, read wiring diagrams, and have circuit wiring experience. Whoever does it turns off the breaker and confirms the power is off at both outlets, with a lamp or a tester just checked on a live outlet, before the cover plate comes off; if it isn't off, Leviton says to stop and call an electrician. And the replacement is a GFCI: Legrand says GFCI outlets should always be used when replacing existing ones.

Prevent It

Test every GFCI after installation, once a month, and after a power failure, per the CPSC; the ESFI adds after every major electrical storm, and Leviton says to test self-test models monthly too. Plug in a lamp and press TEST; the lamp should go out. Press RESET; it should come back on. If either fails, stop using that outlet and have a qualified electrician correct the wiring or replace the GFCI, as the ESFI advises. Pair it with your monthly smoke alarm test, and do it after any power outage. In damp and wet locations, Leviton's instructions call for a weather-resistant (WR) GFCI, and in wet locations a cover or hood that keeps the outlet and plug face dry.

Frequently Asked Questions

Why won't the GFCI reset button push in or stay in?

On GFCIs with a reset lockout, RESET won't hold when there's no power, when line and load are reversed, or when the GFCI has failed its internal test, per Leviton. A fault still on the circuit keeps it tripped, too. Press it firmly once; don't force it. Check the breaker and the other GFCIs, unplug everything, and if it still won't reset, call an electrician.

Why are all the outlets in my bathroom dead?

One tripped GFCI can shut off every outlet downstream of it, including outlets in other rooms. Press RESET on every GFCI in the house and look for a GFCI breaker in the panel. If the outlets are still dead, check for a tripped breaker, then call an electrician.

Why does my GFCI keep tripping?

Suspect a real ground fault first: a damaged cord or appliance, or moisture. Unplug everything, reset, and add things back one at a time. If it trips with nothing plugged in, or the cause isn't obvious, Leviton's advice is to call an electrician.

Can I replace a GFCI with a regular outlet?

No. Replace a GFCI only with a new GFCI. Legrand says GFCI outlets should always be used when replacing existing ones, and the code requires GFCI protection in bathrooms, kitchens, garages, basements, crawl spaces, laundry areas, and outdoors. A regular outlet in its place would also leave every outlet downstream of it unprotected.

The Bottom Line

Find the tripped GFCI and check the breaker, then unplug everything on it and press RESET with dry hands. A GFCI that still won't reset is refusing for a reason: no power, a fault still on the circuit, reversed wiring, or old age. Replace a failed or water-damaged GFCI with a new GFCI, never a regular outlet, using a licensed electrician when in doubt, and test every GFCI monthly with its own TEST button.

Sources

  • Electrical Safety Foundation International — Indoor Electrical Safety Check (PDF) (outlet GFCIs protect downstream outlets, breaker GFCIs the whole circuit; test monthly and after every major electrical storm; a lamp that stays on after TEST means the GFCI isn't working or is miswired, and a qualified electrician corrects the wiring or replaces it) and GFCIs and the National Electrical Code (PDF) (where the 2020 NEC requires GFCI protection in homes, including all basements and outdoor outlets).
  • U.S. Consumer Product Safety Commission — GFCI fact sheet (PDF) (receptacle GFCIs protect downstream outlets; the NEC is adopted and enforced by local jurisdictions; a homeowner with adequate knowledge may install one, otherwise a qualified electrician; test after installation, monthly, and after a power failure, per the manufacturer; power disturbances can damage a GFCI; "No equipment ground" label on ungrounded outlets) and Home Electrical Safety Checklist (PDF) (test GFCIs monthly per the manufacturer; after a shock from an appliance, turn its power off at the breaker and have an electrician check it).
  • National Fire Protection Association — electrical safety in the home (call a qualified electrician for discolored or warm outlets, a burning smell, or sparks; GFCIs installed by a qualified electrician; test after installation and monthly per the manufacturer; replace defective GFCIs immediately).
  • OSHA — Controlling Electrical Hazards, OSHA 3075 (PDF) (a GFCI compares outgoing and returning current and shuts off within as little as 1/40 of a second).
  • UL — New Requirements for GFCIs, UL Question Corner, IAEI News, July–August 2006 (PDF) (effective July 28, 2006: a GFCI outlet at end of life must signal that it needs replacing or stop delivering power, and a miswired one must de-energize its own face as well as the downstream outlets).
  • Leviton — how to reset a GFCI outlet after lockout (no power, a fault still present, line/load reversal, damage; unplug everything and retry; swap reversed wires with the power off, by a licensed electrician unless you are experienced; replace after water exposure, discoloration, cracking, or loose plugs), Reset Lockout Technology (won't reset if miswired, without power, or at end of life; a reversed older GFCI may seem to work but not trip; moisture, surges, and wear), and how to test a Leviton GFCI (monthly test; older GFCIs may reset without protecting).
  • Leviton — what to do when your GFCI trips (PDF) (check appliances in the GFCI and downstream outlets; unplug an obvious cause; call an electrician if it keeps tripping or the cause isn't obvious; replace a discolored, warm, or loose GFCI) and updated GFCI technology (PDF) (electrical noise from variable-speed motors and switching power supplies in modern appliances).
  • Leviton — GFCI instruction sheet (PDF) (LINE and LOAD; protected outlets can be in other rooms; "GFCI Protected Outlet" stickers; lockout without power, when reversed, or after a failed internal test; ships tripped; power off at the panel and confirmed at both outlets, and stop if it isn't; an electrician for boxes with more than four wires; no protection against overloads or short circuits; weather-resistant GFCIs and covers for wet locations; national and local codes), LED indicator light diagnosis (PDF) and self-test GFCI bulletin (PDF) (green, red, and no-light meanings; replace if red continues or it won't reset), self-test brochure (PDF) (test self-test models monthly), and GSCM1-3C specifications (UL 943 Class A; trip level 5 mA plus or minus 1 mA).
  • Legrand (Pass & Seymour) — radiant 20A self-test GFCI, 2097W (self-tests and the indicator flashes when the device fails; power cut when protection is lost or the device is wired incorrectly; use GFCI outlets when replacing existing ones; technical support: trip threshold of 5 ± 1 mA) and what the TEST and RESET buttons do (water among the causes of ground faults; press RESET only after the cause, such as moisture, is fixed; a GFCI that won't reset may need replacing or an electrician).
  • Klein Tools — RT250 GFCI receptacle tester with LCD and instructions (PDF) (3-wire, 120-volt outlets only; voltage, wiring-fault, and GFCI trip-time readout; creates a 6 to 9 mA test fault; check the GFCI's manual first; no GFCI test on a circuit it shows as miswired, open ground included; verify on a known live outlet first; consult a qualified electrician).
  • CenterPoint Energy — flood safety tips (if water has reached the panel or any outlets, don't touch them; the utility disconnects power from outside).

Last reviewed September 29, 2026. General information, not professional advice — rewiring a GFCI, anything inside the panel, and a GFCI that still won't reset with the power on and nothing plugged in belong to a licensed electrician; replace a GFCI yourself only if your local code allows it and you have circuit wiring experience.