Best Heat Tape and Heat Cable for Freeze-Prone Pipes (2026)

Updated By Homeowner Basics EditorsHow we research

As an Amazon Associate we earn from qualifying purchases. Links marked “(paid link)” are affiliate links. Full disclosure.

On this page
  1. At a Glance
  2. Try These Before Heat Tape
  3. Self-Regulating vs. Constant-Wattage Cable
  4. What Actually Matters When Choosing
  5. Heat Tape Safety
  6. Picks Worth Buying
  7. How We Chose
  8. Frequently Asked Questions
  9. The Bottom Line
  10. Sources

The best heat tape for most freeze-prone pipes is a listed, self-regulating cable such as Raychem FrostGuard: Raychem rates it for metal and plastic pipe and says it can't overheat, even where it overlaps. For a straight run, a thermostat cable costs less: the Frost King HC6A for short runs or the EasyHeat AHB for long ones. Whichever you buy, plug it into a GFCI-protected outlet, follow the maker's insulation rule exactly, and inspect it every fall.

Some pipes freeze no matter what you do: the supply line in a vented crawl space, the run along an unheated garage wall, the pipe to a well house. For those, heat tape (makers call it heat cable) is the fix: a cable taped along the pipe that keeps the water from freezing. It is also a product the CPSC has warned about since at least 1989. In 1996 the agency estimated that faulty heat tapes caused about 1,500 fires, 10 deaths, and 100 injuries a year, and it singled out tapes that are old, worn, or improperly installed and maintained. If a pipe is frozen right now, start with our frozen pipes guide instead.

At a Glance

The three picks compared (specifications from each manufacturer)
PickCable typeThermostatPipesBest for
Raychem FrostGuard 6 ft (FG1-6P) (best overall)Self-regulating, about 6 W/ft on a 40°F pipe; may overlapNone; on whenever plugged inMetal or plastic water pipe up to 2-1/2 in.Plastic pipe and runs with valves
Frost King HC6A 6 ft (best budget)Constant wattage, 7 W/ft; never overlapBuilt in: on below 38°F, off about 45°FWater-filled metal or plastic supply pipe up to 1-1/2 in.; instructions include PEX, but the FAQ limits plastic to Schedule 40 and rules out PVCShort, straight runs (kits from 3 to 30 ft)
EasyHeat AHB-140 40 ft (best for long runs)Constant wattage, 7 W/ft; never overlapBuilt in: on at 38°F, off at 45°FWater-filled metal or plastic supply pipe up to 1-1/2 in.Long, straight runs (kits up to 80 ft)

Try These Before Heat Tape

Heat cable is for a pipe that still freezes after the basics. The American Red Cross recommends insulation in attics, basements, and crawl spaces, and sleeves on exposed pipes. Sealing gaps where pipes pass through exterior walls helps too. Keep the heat no lower than 55°F when you're away, and let faucets on exposed runs drip during hard freezes. Drain outdoor faucets before the first freeze (our outdoor faucet guide shows how), and work through the freeze-protection list in our winter home maintenance guide. If a pipe still freezes after all that, add heat cable. The Red Cross lists UL-listed heat tape or heat cable as an option for exposed water pipes. To see whether the next two nights put your pipes at risk, use our pipe freeze check.

Already have heat tape? A house you just bought may have it on some pipes. In a 1990 review of heat tape fires, the CPSC found that many homeowners didn't regularly inspect their heat tapes, and some didn't know one had been installed. Check the crawl space, the garage, and any supply line in an unheated space. Inspect any tape you find before winter, and replace one with no testing-lab listing or of unknown age.

Self-Regulating vs. Constant-Wattage Cable

Constant-wattage cable

Constant-wattage cable puts out the same heat per foot along its whole length whenever it is on: 7 watts per foot for the Frost King and EasyHeat kits below. Nothing turns a hot section down, so any spot where the cable touches itself runs hotter. EasyHeat warns that overlapped contact points can exceed ignition temperatures. These cables run straight along the pipe and are never spiraled, crossed, or overlapped. A built-in thermostat turns them on when the pipe drops below about 38°F and off at about 45°F.

Self-regulating cable

Self-regulating cable adjusts its output at each point to the temperature there. Raychem's FrostGuard puts out about 6 watts per foot on a 40°F pipe and less as the pipe warms, and Raychem says it can't overheat even when overlapped or closely spaced, so you can spiral it or wrap extra around a valve. The trade-off: FrostGuard has no thermostat, so it's energized whenever it's plugged in.

What that means for plastic pipe

PEX, PVC, and other plastic pipe need a cable its maker rates for that pipe. Raychem rates FrostGuard for metal and plastic water pipes, with a separate length chart for plastic, and EasyHeat rates the AHB for water-filled plastic supply pipe, including PEX. Frost King's guidance is mixed: its instructions allow water-filled plastic supply pipe, including PEX, but its FAQ limits plastic to Schedule 40 supply pipe from 3/8 to 1-1/2 inches, says its kits aren't made for PVC, and rules out flexible lines such as mobile home feed lines. For PEX or PVC, FrostGuard or the AHB is the clearer choice. The constant-wattage makers add conditions: the pipe must stay full of water, and Frost King and EasyHeat both recommend wrapping plastic pipe in aluminum foil first so the heat spreads evenly. None of them goes on a garden hose or flexible vinyl tubing.

What Actually Matters When Choosing

Rated for your pipe

Match the cable to the pipe's material, diameter, and contents. FrostGuard covers metal or plastic water pipes up to 2-1/2 inches; the Frost King and EasyHeat kits cover water-filled supply pipes up to 1-1/2 inches. The CPSC says never to use heat tape designed for water pipes on gutters, driveways, or fuel lines; for the roof and gutters, see our roof de-icing cable guide. The 120-volt FrostGuard is designed for both pipes and roof-and-gutter de-icing, with separate Raychem instructions for each; Raychem doesn't rate it for driveways or fuel lines.

Length sized to the run, valves included

The CPSC says to measure the pipe's diameter and length, then buy the cable its manufacturer recommends for that size. For FrostGuard, Raychem says to add 1 foot per valve or spigot and to spiral any extra cable evenly along the pipe. Constant-wattage cable is different: never cut it or spiral it to use up extra length. Frost King says never to use a cable longer than the pipe; EasyHeat lets the non-thermostat end double back up to 3 feet along the opposite side of the pipe, never touching or crossing itself. For runs between standard lengths, Frost King allows a cable up to 2 feet shorter than the pipe on 3/8- to 3/4-inch pipe, and two separate cables on opposite sides of 1- to 1-1/2-inch pipe. Neither kit goes on a pipe shorter than 3 feet.

The thermostat, and where it goes

Frost King says to tape the thermostat tight against the pipe at its coldest end and insulate over it. Placement varies by model, so the CPSC says to check whether yours goes against the pipe under the insulation or hangs uncovered.

Plug-in vs. hardwired

All three picks are plug-in kits with a lighted, grounded three-prong plug, and the CPSC says to always use a three-prong outlet so the tape is grounded. Hardwired kits, such as Raychem's 240-volt FrostGuard, whose cord is meant to be connected in a junction box, need an electrician. Raychem and Frost King both say never to install heat cable in walls, floors, or ceilings.

The outlet: GFCI, and kept dry

The CPSC says to plug heat tape into an outlet protected by a ground-fault circuit interrupter (GFCI). Raychem requires ground-fault protection because arcing from a damaged cable may not trip an ordinary breaker, and EasyHeat says the AHB must be GFCI protected. Frost King strongly recommends it. EasyHeat notes that the heat tape outlet in a manufactured home built before 2014 wasn't GFCI protected when built; if you're not sure about yours, have an electrician check it or add a GFCI outlet. EasyHeat also allows a portable GFCI cord for the AHB; Raychem prohibits extension cords, so FrostGuard needs a GFCI-protected outlet. Raychem also requires an outlet protected from rain, and the CPSC says to keep the end cap sealed and off the ground. If the GFCI trips, the cable may be damaged: unplug it and inspect its whole length before you reset the GFCI. If it trips again, replace the cable or call an electrician. Never move it to an outlet without GFCI protection. Our breaker guide covers resetting a GFCI safely.

Insulation over the cable: follow the maker exactly

The CPSC's rules: put heat tape directly on the pipe, never over existing insulation. Don't cover it with insulation unless the manufacturer says to. If you do, use non-flammable insulation such as fiberglass, not foam or vinyl that could catch fire from a failing tape. Never use more insulation than the maker recommends; over-insulation can cause a fire.

The makers' limits differ. The constant-wattage kits set a maximum of 1/2 inch of non-flammable insulation: fiberglass or equivalent for Frost King, fiberglass (with a vapor seal) or non-flammable foam for EasyHeat. Raychem sets a minimum for FrostGuard: at least 1/2 inch of fire-resistant, waterproof insulation such as preformed foam or fiberglass, or 1 inch where temperatures reach -20°F. The simplest choice that satisfies the CPSC and all three makers in most climates is half-inch fiberglass pipe wrap with a vapor seal or waterproof outer wrap (1 inch over FrostGuard where temperatures reach -20°F). Don't put ordinary foam sleeves meant for bare pipe over heat cable.

Heat Tape Safety

These rules come from the CPSC and the makers' instructions, and none of them bend.

Every fall, unplug the cable and inspect its entire length. Replace it at once if you see cracked or charred insulation, discoloration (especially at the plug), cuts, or bare wire. Never repair heat cable. Plug it only into a grounded, GFCI-protected outlet. Never wrap it over itself unless its installation instructions specifically permit it, and never wrap it over existing insulation.

  • Buy only listed cable. The CPSC urges replacing uncertified heat tapes more than three years old with tapes certified to UL, CSA, or FM standards, which have a much better safety record. All three picks carry a UL or CSA mark.
  • Use it only on pipes it's rated for. Never on hoses, flexible tubing, or fuel lines, or on pipes hotter than the rating (150°F for FrostGuard, 155°F for Frost King). Reread the instructions when you switch brands; the CPSC notes the requirements often differ.
  • Use GFCI protection every time, as the CPSC says, even where a maker only recommends it.
  • Skip extension cords unless the maker allows one. Raychem prohibits them. Frost King allows one only if necessary: a properly sized, grounded, UL- or CSA-certified cord suitable for outdoor use. Better: have an electrician add a GFCI outlet within reach.
  • Inspect every season. The CPSC says every fall; Frost King says at the start of the season and monthly while in use, including for animal chewing. In six years of fire data the CPSC reviewed in 1990, mobile homes and trailers accounted for more than half of heat tape fires, and it says most people should have a qualified electrician inspect.
  • Replace, don't repair. Raychem says never to repair or energize a damaged cable, and Frost King says its cable has no serviceable parts.
  • Install before the deep cold (minimum 15°F for Frost King and EasyHeat, 5°F for FrostGuard), and never plug in a cable while it is still coiled.
  • Keep combustibles away. EasyHeat says no combustible material, including cellulose insulation, paper, or wood, within 1 inch of the pipe; follow your own cable's clearance rule. Keep working smoke alarms on every level; see our smoke alarm guide.
  • Add a backup alert. A leak sensor with a freeze alert beside the protected pipe warns you if the cable, its thermostat, or its GFCI quits.

Picks Worth Buying

1. Best overall — self-regulating and forgiving

Best overallnVent RAYCHEM 120V FrostGuard Pipe Freeze Protection, 6 ft (FG1-6P)a self-regulating plug-in cable for metal or plastic water pipes up to 2-1/2 inches that Raychem says can't overheat, even overlapped.check price on Amazon

FrostGuard is the hardest cable here to install wrong, since extra wraps around a valve won't create a hot spot. The 120-volt kit comes in lengths from 6 to 100 feet, each with a 6-foot cord and a lighted, grounded plug; the link is the 6-foot kit, so buy the length Raychem's chart gives for your pipe. Raychem requires a ground-fault protected outlet and waterproof, fire-resistant insulation, prohibits extension cords, and says to fasten the cable with fiberglass tape or nylon ties, not vinyl electrical tape or duct tape. The Raychem brand now belongs to Chemelex, so newer packaging may not say nVent.

Our verdict

Best for: plastic pipe, runs with valves and fittings, and anyone who wants the most forgiving install.

Pros: tolerates overlap, suits plastic pipe, widest pipe range here, CSA certified, installs down to 5°F.

Cons: no thermostat, so it draws power whenever it's plugged in, even on mild days; costs more than the constant-wattage kits; insulation over it is required.

2. Best budget — a thermostat kit for short runs

Best budgetFrost King HC6A Automatic Electric Heat Kit Heating Cables, 6 Feeta 7-watt-per-foot cable with a built-in thermostat for short runs of water-filled metal or plastic supply pipe.check price on Amazon

Frost King's kit is the classic hardware-store heat cable, with a built-in thermostat that turns it on below 38°F and off at about 45°F and a plug with a power light. Kits run from 3 to 30 feet (HC3A through HC30A); the 6-foot HC6A suits a short exposed riser or a crawl-space run to a hose bib. The instructions are strict: run the cable straight along the bottom of the pipe, tape it every 6 inches with tape rated to at least 176°F, seat the thermostat at the pipe's coldest end, and cover it all with no more than 1/2 inch of non-flammable insulation plus a waterproof overwrap. It protects pipes up to 1-1/2 inches.

Our verdict

Best for: short, straight runs of supply pipe in a crawl space or garage.

Pros: the thermostat limits running time; a simple install; many short lengths; budget price; UL and CSA marks.

Cons: it can never overlap, which makes valves awkward; the 1/2-inch insulation cap; a 12-month warranty; and Frost King only recommends a GFCI, where the CPSC says to use one every time.

3. Best for long runs — a thermostat cable up to 80 feet

Best for long runsEasy Heat AHB-140 Heat Cable, 40 Feeta UL-listed, 7-watt-per-foot cable with a built-in thermostat for water-filled metal or plastic supply pipes, sold in lengths up to 80 feet.check price on Amazon

EasyHeat's AHB line works like the Frost King kit, with a built-in thermostat that turns on at 38°F and off at 45°F and a lighted plug, but it goes longer: 3-foot steps up to 18 feet, then longer lengths up to 80 feet. EasyHeat sizes the AHB-140 linked here for pipes 37 to 41 feet long; for any other length, use the AHB model its chart gives (from AHB-013 for 3 to 4 feet up to AHB-180 for 77 to 81 feet). At 7 watts per foot, it draws about 280 watts. The rules match Frost King's: run it straight, never spiral, cross, overlap, cut, or splice it, and cover it with no more than 1/2 inch of non-flammable insulation. It fits pipes up to 1-1/2 inches, and EasyHeat says the outlet must be GFCI protected.

Our verdict

Best for: long, straight runs of supply pipe in a crawl space or unheated basement.

Pros: UL listed; thermostat; lengths far beyond Frost King's 30-foot maximum; a clear GFCI requirement.

Cons: keeping 40 feet of cable straight and clear of itself takes planning around valves; one-year limited warranty; 15°F minimum installation temperature.

How We Chose

We compare the category first — what a first-time homeowner actually needs from heat tape — then weigh manufacturer specifications, verified buyer feedback, and how the product type is used in real homes. For this guide we also read each maker's full installation instructions and required a testing-laboratory listing. We don't accept free products or payment for placement, and every pick names its compromise. How we research and review.

Frequently Asked Questions

Can you leave heat tape plugged in all the time?

Through the cold season, yes: that's how it's designed to work, as long as it is listed, on a grounded GFCI outlet, installed exactly per its instructions, and inspected every fall. Thermostat models heat only when the pipe nears freezing. EasyHeat says the AHB can stay installed year round, while Frost King recommends turning its cable off or unplugging it at the end of the season, once air temperatures stay above 50°F. FrostGuard has no thermostat, so it draws power whenever it's plugged in, even on mild days.

Does heat tape work on PEX or PVC pipe?

Yes, if the maker rates the cable for that pipe. Raychem's FrostGuard and EasyHeat's AHB (which names PEX) are rated for plastic water pipe; Frost King's instructions include PEX, but its FAQ limits plastic to Schedule 40 pipe and rules out PVC, so for PEX or PVC choose one of the other two. Constant-wattage cables need the pipe full of water at all times, and their makers recommend wrapping it in aluminum foil first.

Can I put foam pipe insulation over heat tape?

No. The CPSC says to use non-flammable insulation such as fiberglass, not foam or vinyl that could catch fire from a failing tape, and never more than the cable's maker allows. Half-inch fiberglass wrap with a vapor seal meets that rule and the instructions for all three picks, except that Raychem calls for 1 inch over FrostGuard where temperatures reach -20°F. Ordinary foam sleeves are for bare pipe. Raychem's instructions allow fire-resistant preformed foam over FrostGuard, but fiberglass satisfies Raychem and the CPSC both.

How long does heat tape last?

None of these makers gives a fixed lifespan, and the warranties are short: 12 months for the Frost King and EasyHeat cables, and Raychem lists a two-year product warranty as available for FrostGuard. So condition decides. Replace a cable when an inspection turns up cracks, charring, discoloration, cuts, or bare wire. The CPSC also urges replacing any uncertified heat tape more than three years old. If you've just moved in and found heat tape with no listing mark or of unknown age, replace it.

Is heat tape the same as heat cable?

For pipe freeze protection, yes. "Heat tape" is the everyday name; Raychem, Frost King, and EasyHeat sell the product as heating cable or heat cable, and the CPSC and the Red Cross use the terms together. What matters is the type, self-regulating or constant-wattage, explained above.

Can heat tape be buried or run underground?

Not these kits. Frost King and EasyHeat both say their cable must not be buried or come in contact with the ground, and Raychem's FrostGuard instructions don't cover buried pipe at all. Some guides suggest running heat tape down into the soil to the frost line; the makers of the two constant-wattage picks say no. If a pipe freezes where it comes out of the ground, protect the exposed part and ask a plumber about the buried section.

How much electricity does heat tape use?

Multiply the watts per foot by the length. The Frost King and EasyHeat cables put out 7 watts per foot while they're on, so the 6-foot HC6A draws about 42 watts and the 40-foot AHB-140 about 280 watts, and their thermostats switch them on only below about 38°F. Running nonstop for a full day, that's roughly 1 kWh for the 6-foot cable and 6.7 kWh for the 40-foot one, and less whenever the thermostat cycles off. FrostGuard puts out about 6 watts per foot on a 40°F pipe and less as the pipe warms, but with no thermostat it draws some power whenever it's plugged in. Your utility bill shows what you pay per kWh.

What should hold heat tape on the pipe?

Whatever the maker names, and never wire or metal clamps. Frost King and EasyHeat call for their own application tape or good-quality electrical tape rated to at least 176°F (80°C), with the cable laid straight along the pipe, not spiraled. Frost King warns that other adhesive tapes can let the cable move at operating temperature, which could cause overheating or fire. For FrostGuard, Raychem calls for fiberglass tape or nylon cable ties, not vinyl electrical tape or duct tape.

The Bottom Line

Insulate, seal drafts, and keep the heat at 55°F or higher when you're away. For a pipe that still freezes, the Raychem FrostGuard is the most forgiving choice, especially on plastic pipe or around valves. For short, straight runs on a budget, choose the Frost King HC6A or the length in its line that fits. For long runs, choose the EasyHeat AHB-140 or the AHB length that matches your pipe. Whichever you buy, use a GFCI outlet, follow the maker's insulation rule exactly, and inspect it every fall.

Sources

  • U.S. Consumer Product Safety Commission — heat tape safety guidelines, reissued 1996 (about 1,500 fires, 10 deaths, and 100 injuries a year from faulty heat tapes; replace uncertified tapes more than 3 years old with tapes certified to UL, CSA, or FM standards; reread instructions when changing brands; three-prong grounded plug; GFCI-protected outlet; no wrapping over itself unless the maker permits; directly on the pipe, never over insulation; end cap sealed and off the ground; no insulation over the tape unless the maker advises, non-flammable such as fiberglass, not foam or vinyl; not on gutters, driveways, or fuel lines; thermostat placement per the instructions; inspect every year).
  • U.S. Consumer Product Safety Commission — check heat tapes and cables for possible fire hazards (inspect in the fall; replace damaged tape; buy tape recommended for the pipe's diameter and length; never more insulation than the maker recommends) and mobile homes: have heat tapes and cables checked (over half of heat tape fires involved mobile homes and trailers; many owners didn't inspect or didn't know a tape was installed; most consumers should have a qualified electrician inspect).
  • American Red Cross — frozen pipes (insulate attics, basements, crawl spaces, and exposed pipes; UL-listed heat tape or heat cable on exposed water pipes; heat no lower than 55°F when away).
  • Chemelex (Raychem) — FrostGuard plug-in kit, datasheet (PDF), and 120 V installation instructions (PDF) (self-regulating; no overheating even when overlapped; 6 to 100 ft with a 6 ft cord and lighted plug; metal or plastic pipe up to 2-1/2 in.; about 6 W/ft on a 40°F pipe; ground-fault protection required; no extension cord; at least 1/2 in. of fire-resistant, waterproof insulation, 1 in. to -20°F; add 1 ft per valve or spigot; never repair damaged cable; 5°F minimum installation temperature; CSA mark; 2-year product warranty available).
  • Frost King — automatic electric heat cable kits and installation instructions (PDF) (3 to 30 ft, 120 V, 7 W/ft; thermostat on below 38°F, off about 45°F; pipes up to 1-1/2 in.; never overlap or spiral; never longer than the pipe; max 1/2 in. of non-flammable insulation; plastic pipe must stay water-filled, foil wrap recommended; GFCI strongly recommended; plastic pipe including PEX per the instructions, while the FAQ says copper, iron, or Schedule 40 plastic only, not PVC or mobile home feed lines; up to 2 ft shorter than the pipe on 3/8 to 3/4 in., two cables on 1 to 1-1/2 in.; extension cord only if necessary and outdoor-rated; inspect at season start and monthly; may stay on the pipe year round, but turn off or disconnect power at the end of the season, when air temperatures stay above 50°F; 15°F minimum installation temperature; 12-month warranty; UL and CSA marks).
  • EasyHeat (Emerson) — AHB cable (constant wattage, 120 V, UL Listed, built-in thermostat, metal and plastic supply pipes, never overlap, one-year warranty) and the AHB installation manual (PDF) (water-filled metal or plastic supply pipe including PEX; can remain installed year round, with the thermostat shutting it off when heat isn't needed; non-thermostat end may double back up to 3 ft; combustibles at least 1 in. from the pipe; pre-2014 manufactured home heat tape outlets not GFCI protected; thermostat on at 38°F, off at 45°F; pipes up to 1-1/2 in.; GFCI required; max 1/2 in. of non-flammable insulation; foil wrap on plastic pipe; 15°F minimum installation temperature; models AHB-013 to AHB-180 (80 ft); AHB-140 for 37 to 41 ft of pipe; GFCI trips mean inspect, then replace or call an electrician if it trips again).
  • EasyHeat (Emerson) — AHB cable catalog page, October 2017 (PDF) (7 W/ft; 3 ft steps to 18 ft, longer lengths to 80 ft; on at 38°F, off at 45°F; GFCI required per the NEC and CEC).

Last reviewed October 2, 2026. General information, not professional advice — adding an outlet, hardwiring a heat cable, and any damaged wiring belong to a licensed electrician, and a pipe that has already split belongs to a plumber.