AC Won't Turn On: What to Check and When to Call
Time 15–30 minutesDifficulty Easy
On this page
Central air that won't start is usually being stopped before it begins: the thermostat isn't calling for cooling, a breaker or switch has cut power to the indoor or outdoor unit, a float switch has shut the system down over water in the drain pan, or a built-in delay is still running. Carrier and Bryant both say a tripped breaker, a thermostat setting, or a clogged filter is the most common cause. A failed part in the outdoor unit, such as the capacitor or contactor Lennox names, is a technician's repair.
If the system runs but the air isn't cold, see AC not cooling; if there's ice on the indoor coil or copper lines, see AC frozen coil.
Keep your hands out of the outdoor unit. Its capacitor stores a charge that Carrier warns "can cause serious injury or death, even when the power is disconnected," so never open the unit's electrical panel. Touch the breaker panel only with dry hands and never while standing in water; if water has reached the panel, stay out and call the electric utility to cut power from outside. If there is smoke or fire, get everyone out and call 911 from outside. If the house is dangerously hot, read staying safe while you wait first.
Check these in order:
- Thermostat: batteries, COOL, a lower setpoint, fan on AUTO.
- The delay: wait 5 minutes after any restart.
- Breakers: the indoor unit's and the outdoor unit's.
- Switches and water: service switch, blower door, outdoor disconnect, float switch.
- A humming outdoor unit: turn the system off and call.
Most Likely Causes, by What You See
First notice what runs. Lennox says a working outdoor unit makes at least a low hum and its fan blades spin.
The Thermostat Screen Is Blank
- Dead batteries. Trane's first check: a blank screen may need new batteries. Lennox says fresh ones are often the whole fix on a battery-powered model.
- The system has lost power. A hardwired thermostat draws power from the HVAC equipment, usually through a C-wire, Lennox explains. Honeywell's checks for a blank display: the circuit breaker, the power switch at the heating and cooling system, a securely closed furnace door, and a connected C wire. The first three are under nothing runs at all; for the last, see our C-wire guide.
- A tripped float switch. Lennox lists it too: water backed up from a clogged drain line trips the switch, which cuts system power to prevent water damage.
- A blown fuse or failed transformer. Lennox says a power surge can take out either, and the transformer is built into the HVAC system. Both are technician repairs; our thermostat troubleshooting page covers the fuse.
The Indoor Fan Runs, but the Outdoor Unit Is Silent
Set the thermostat to OFF between checks: Lennox says running the indoor fan alone "adds heat without cooling."
- Thermostat settings. Trane says COOL, fan on AUTO, and a set temperature below the indoor temperature. Lennox suggests 3 to 5 degrees below room temperature, then a few minutes' wait.
- A built-in delay. Carrier's owner's manual says some units have built-in time delays to protect the equipment. Honeywell says a flashing Cool On on its RTH6500WF means compressor protection: wait 5 minutes. Bryant describes a "3-minute rule" that keeps a compressor from restarting too soon. After a power blip, a breaker reset, or a settings change, give it 5 minutes.
- The outdoor unit's breaker. Carrier says the outdoor and indoor units have separate breakers, the outdoor one usually 220 or 240 volts, and Trane says to check both. See how to reset one.
- The disconnect box by the outdoor unit. Carrier and Bryant say to check it. Rheem's check before calling for service: the disconnect's fuses are in good condition and the power is on. If it's off and nobody switched it off for service, turn it on with dry hands. A blown fuse in it, Bryant says, usually needs professional replacement.
- A frozen coil. Trane says a clogged filter can freeze the evaporator coil and shut the AC off; Lennox says a refrigerant leak can do the same and trip a low-pressure switch that protects the compressor. If you see ice, Carrier says to shut the system off; see AC frozen coil. A dirty filter is yours to replace (filter guide).
- A failed part outside. With a cooling call and power on, Lennox points to a failed capacitor or contactor or a worn fan motor; Trane adds loose wiring and the compressor motor. All are technician repairs.
If other 240-volt appliances quit too, Florida Power & Light says damaged utility service leads can be the cause; see half the house has no power.
The Outdoor Unit Hums but Won't Start
Carrier says a hum from the outdoor unit usually means a motor is trying to start without the torque its capacitor supplies, and "the AC unit humming but not starting" is among the signs its technicians see most. Lennox agrees.
- Turn the system off at the thermostat. Carrier recommends not running an AC with a bad capacitor, which can permanently damage the compressor and fan motors. Bryant says to turn the system off for buzzing, grinding, or hissing and call a qualified HVAC professional.
- Don't open the unit. Lennox says a capacitor can carry a residual charge that could seriously hurt you. Bryant says not to disassemble the outdoor unit, and Trane says only a trained technician should touch its wiring.
- Tell the technician what you heard. Lennox notes humming has other possible causes, so the diagnosis is theirs.
Nothing Runs at All
When a thermostat loses power, Lennox says, the equipment "has no instructions to follow," so start indoors.
- Settings, then the fan test. With COOL and a lower setpoint confirmed, set the fan to ON: Rheem says the indoor blower should start immediately. If it doesn't, check the power below; then set it back to AUTO.
- The furnace or air handler breaker. Lennox says an air handler has its own dedicated circuit, and a trip cuts its power completely.
- The service switch. Trane says a furnace's shutoff switch may look like a light switch next to it; Lennox says some air handlers have a disconnect or breaker on the unit. Make sure it's on. If you smell gas at the furnace, don't touch the switch: leave the house without switching anything on or off or using a phone inside, and call 911 and the gas utility once you're a safe distance away.
- The blower door. If the furnace's blower door is off or ajar, Trane's fix is to close it "to restore power to the furnace and the gas valve." Turn the service switch off, seat the panel, then turn it on. Carrier's furnace instructions say never to tape or bypass the door switch. More in our furnace guide.
- A tripped condensate float switch. Trane says a clogged drain line can shut the system down if it has a condensate safety switch; Lennox says the switch trips when water in the pan under the indoor coil rises too high. Look for water in the pan or around the indoor unit. Clearing the drain removes the trigger, Lennox says; our condensate line guide shows how.
How to Reset a Tripped AC Breaker
The ESFi notes a tripped breaker can rest close to ON, so look carefully. Open only the panel's hinged door; the CPSC says panel boxes are usually live even with the main breaker off, so the screwed-on cover behind the door stays on for a licensed electrician.
- Dry hands, dry floor. The ESFi says never to handle electrical items when wet, and CenterPoint Energy says to cut power only if the area around the panel is completely dry.
- Thermostat to OFF, Carrier's first reset step.
- Breaker fully to OFF, then ON, as the ESFi describes. Once.
- Thermostat to COOL, then wait 5 minutes.
- If it trips again, leave it off and call. Carrier says an immediate re-trip signals a deeper electrical fault; our breaker page explains why a second trip means stop.
Trane is stricter: it says not to flip a tripped AC breaker at all but to call an HVAC professional, because resetting it without knowing why it tripped could damage the system. Carrier says to reset one only if you're comfortable. If water has reached the panel, CenterPoint says don't touch it; call the utility to disconnect power from outside.
What You Can Fix Yourself
- Thermostat batteries, mode, setpoint, fan, and schedule.
- One breaker reset, the service switch, the blower door, and a disconnect left off.
- A clogged condensate drain.
- A dirty filter: Trane says replace it and try again, and call if the AC still won't run.
- Leaves and clippings on the outdoor coil, removed with the power off, without bending the aluminum fins, per Rheem.
Everything else is the technician's. Rheem says "under no circumstances should the Homeowner attempt to install and/or service the equipment," and Goodman says homeowners shouldn't open any equipment.
When to Call a Pro
- A breaker trips again, or a disconnect fuse may be blown.
- The outdoor unit hums or buzzes but won't start (Carrier, Bryant).
- The outdoor unit stays silent with a cooling call and power on: Lennox and Trane name the capacitor, contactor, fan motor, loose connections, and compressor, and Lennox adds the control board.
- Ice or a suspected refrigerant leak. The EPA requires Section 608 certification for technicians who service equipment that could release refrigerant, prohibits venting it, and limits refrigerant sales for home air conditioners to certified technicians.
- Water keeps coming back in the drain pan (Lennox).
- A burning or electrical smell near the unit, which Lennox says needs a pro right away. Turn the system off at the thermostat meanwhile.
Tell the technician what you saw and heard, and have each unit's model and serial numbers ready, as Carrier's manual suggests. If the system is past 15 years old and the compressor has failed, Trane and Bryant suggest weighing replacement against repair.
Staying Safe While You Wait
The CDC's heat guidance:
- Fans only below 90°F indoors; above that, the CDC says, a fan can increase body temperature.
- Get to air conditioning. Find a place that has it by dialing 2-1-1, checking the National Center for Healthy Housing's Cooling Centers by State page, or calling your local health department or emergency management agency.
- Drink water through the day and check on others, especially people who live alone. The CDC names people 65 and older, infants and young children, pregnant women, and people with heart disease or asthma as higher risk.
- Heat stroke is a 911 call. A temperature of 103°F or higher, hot, red, dry, or damp skin, a fast, strong pulse, confusion, or passing out: call 911 right away, move the person somewhere cooler, cool them with cool cloths or a cool bath, and give them nothing to drink.
- Heat exhaustion: heavy sweating, cold, pale, clammy skin, nausea, dizziness, or fainting. Move to a cool place, loosen clothes, use cool, wet cloths, and sip water. Get medical help right away if you're throwing up, symptoms get worse, or they last longer than an hour.
Prevent It
ENERGY STAR recommends a contractor check-up of the cooling system each spring, including tightening electrical connections, checking the controls and starting cycle, and inspecting the condensate drain. Carrier says annual tune-ups catch a capacitor drifting out of range before it fails. Check the filter monthly (ENERGY STAR), keep plants at least two feet from the outdoor unit (Trane, Bryant), flush the drain line with a little white vinegar every few months (Lennox), and replace thermostat batteries yearly (Lennox). Our summer maintenance guide covers the rest of the season.
Frequently Asked Questions
Why won't my AC turn on when the thermostat is on?
Confirm COOL, a setpoint below room temperature, and the fan on AUTO, then wait 5 minutes for the compressor delay. Then check both breakers, the service switch, the blower door, the outdoor disconnect, and the drain pan.
Why is my outdoor AC unit not running when the inside fan is?
Usually its breaker, its disconnect, or the delay. If those check out, Lennox points to the capacitor or contactor, both technician repairs. Turn the system off meanwhile.
How do I reset my central air?
Carrier's reset: thermostat off, AC breaker off, wait at least 30 minutes, breaker on, thermostat to COOL. Do it once. A breaker that trips again stays off until a technician looks.
Can I replace an AC capacitor myself?
No. Carrier strongly recommends against it because of the stored high voltage, and Lennox says not to replace one yourself. Call a licensed HVAC technician.
The Bottom Line
Thermostat, a 5-minute wait, both breakers, the switches, the outdoor disconnect, and the drain pan. Reset a breaker once with dry hands. Humming, a silent outdoor unit with power on, ice, and refrigerant go to an HVAC technician; the outdoor unit stays closed. If the house is dangerously hot, get to air conditioning.
Sources
- Carrier — troubleshoot an air conditioner (a tripped breaker, a thermostat setting, or a clogged filter most often; check the disconnect box near the outdoor unit; reset a breaker only if comfortable, and not again if it trips immediately, a deeper electrical fault; shut the system off if you see ice; the reset: thermostat off, AC breaker off, wait at least 30 minutes, breaker on, thermostat to Cool), what is an AC capacitor? (a hum from the outdoor unit means a motor lacking the capacitor's torque; humming but not starting is a top sign; don't run an AC with a bad capacitor; homeowners should not replace one, since it stores high voltage that can cause serious injury or death even with the power disconnected; annual tune-ups catch a drifting capacitor), heat pump not heating (the outdoor unit, usually on a 220- or 240-volt breaker, and the indoor unit have separate breakers), plus the split-system air conditioner owner's manual, OG-ACR410GEN-03 (PDF) (built-in time delays protect the equipment; have the model and serial numbers ready when you call) and the 58SC0B gas furnace instructions (PDF) (do not tape or bypass the blower door switch).
- Trane — AC not turning on (a blank screen may need batteries; COOL, fan on AUTO, set temperature below indoor temperature; the indoor shutoff switch looks like a light switch next to a furnace, and an air handler has none; check the breaker for the indoor or outdoor unit, and call a professional rather than flip a tripped one; a clogged filter can freeze the coil, so replace it and call if the AC still won't run; a condensate safety switch can shut the system down; a bad capacitor keeps the unit from starting; consider replacement past 15 years), central AC compressor not turning on (flipping a tripped breaker back on without knowing why could damage the system; loose connections, and only a trained technician should touch the wiring; the compressor motor; repair or replace a dead compressor; landscaping two feet from the outdoor unit), and furnace blower not working (close the blower door to restore power to the furnace and gas valve).
- Lennox — outdoor AC unit not turning on (a failed capacitor or contactor can prevent startup; avoid running the indoor fan alone; a low hum and spinning fan blades; 3 to 5 degrees below room temperature; humming and a failed capacitor; a worn fan motor; a refrigerant leak and the low-pressure switch; the float switch in the evaporator drain pan), air handler not turning on (its own dedicated circuit; a disconnect or breaker on the unit; the control board; a burning smell or water that keeps coming back means a pro; vinegar for the drain line every few months), no power to thermostat (fresh batteries; hardwired thermostats powered by the HVAC unit through a C-wire; equipment with no instructions to follow; a surge can take out the fuse or the transformer built into the HVAC system; the float switch cuts system power; yearly battery changes), and what's an AC capacitor? (humming has other possible causes; don't replace a capacitor yourself; a residual charge that could seriously hurt you).
- Bryant — why is my AC not working? (a tripped breaker, a thermostat setting, or a clogged filter; check the outdoor disconnect switch; two feet of clearance; for buzzing, grinding, or hissing, turn the system off and call; don't disassemble the outdoor unit; the 3-minute rule; a blown disconnect fuse usually needs professional replacement; replacement for systems over 15 years old that need a major repair).
- Rheem — outdoor air conditioner user's information and installation instructions (PDF) (fan ON starts the indoor blower immediately; remove leaves and grass clippings from the coil with the power disconnected, without damaging the fins; before calling service, the disconnect fuses are good and the power is on; the homeowner should never attempt to service the equipment) and M3RL furnace instructions (PDF) (if you smell gas, don't touch any electrical switch or use any phone in the building, and leave).
- Goodman — the urgent AC repair service call (a homeowner should not open equipment, even to find the model number).
- Honeywell Home (Resideo) — RTH6500WF user guide (PDF) (blank display: breaker, system power switch, furnace door, C wire; a flashing Cool On means compressor protection, so wait 5 minutes).
- Florida Power & Light — power disturbances FAQ (damaged service leads can leave only 120-volt outlets working, with 240-volt appliances such as air conditioning out).
- Electrical Safety Foundation International — Indoor Electrical Safety Check (PDF) (a tripped breaker can rest close to ON; move it fully to OFF, then ON) and Outdoor Electrical Safety Check (PDF) (never handle electrical items, plugs, or outlets when wet).
- U.S. Consumer Product Safety Commission — arc fault circuit interrupters (PDF) (panel boxes are usually live even with the main breakers off; that work is for a qualified electrician).
- CenterPoint Energy — flood safety tips (cut power only if the area around the panel is completely dry; if water has reached the panel, don't touch it, and call the utility to disconnect power from outside).
- ENERGY STAR — maintenance checklist (a contractor check-up of the cooling system in spring; tighten electrical connections; check controls and the starting cycle; inspect the condensate drain; check filters monthly).
- U.S. Environmental Protection Agency — Section 608 technician certification (technicians who service equipment that could release refrigerants must be certified), stationary refrigeration and air conditioning (no intentional venting of refrigerants during service), and refrigerant sales restriction (only Section 608-certified technicians can buy refrigerant for stationary air conditioning).
- Centers for Disease Control and Prevention — about heat and your health (fans only below 90°F indoors; find air conditioning through 2-1-1, the cooling-centers page, or the local health department or emergency management agency; drink throughout the day; check on others; groups at greater risk) and heat-related illnesses (PDF) (heat stroke signs; call 911 right away, move the person somewhere cooler, cool cloths or a cool bath, nothing to drink; heat exhaustion signs and steps; when to get medical help).
- U.S. Fire Administration — home fire escape plans (get outside, then call the fire department).
Last reviewed October 3, 2026. General information, not professional advice — capacitors, contactors, compressors, control boards, wiring, and refrigerant belong to a licensed HVAC technician, and anything behind the electrical panel's cover belongs to a licensed electrician.